Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13604142

- Product Categories
- Friendly Links
Information Name: | Sales / purchase / lease Agilent8714ET Network Analyzer 8714ET |
Published: | 2014-11-11 |
Validity: | 30 |
Specifications: | |
Quantity: | 10.00 |
Price Description: | |
Detailed Product Description: | City Feiyu Electronic Instrument Co., Ltd. Contact: Miss Meng Mobile: 13688968946/13027646696 Fax: 0769-87912842 E-mail: staytar@163.com QQ: 494557942 Company website: http: //www.yt5117.com.cn Address: Dongguan Welcome Avenue Tong Fu Road, Tangxia Town, City, No. 144 Agilent / HP 8714ET network analyzer 3GHZ Used detailed description of Agilent / HP 8714ET network analyzer 3GHZ Used RF Network Analyzer 8712ES 8712ET 8714ES 8714ET rate range: 300KHz ~ 1.3GHz (3.0 GHz) S-parameter measurements of narrowband and broadband detection 100dB dynamic range real-time scanning speed (50ms / scan) 50Ω or 75Ω system impedance synthesized signal source standard 1 Hz resolution, LAN (Local Area Network) interface standard Agilent Instrument BASIC (IBASIC) available Standard 2, 6 and 12-port adapter testing device can be used to locate and Confederate SRL (structural return loss) measure designed with the needs of the manufacturing economy Agilent 8712E Series RF network analyzer in a compact, integrated instrument in the form of a large number of manufacture of RF components to provide fast, accurate and automated features, such Analyzer helps reduce test time, increase productivity and reduce the total cost of each component. Transmission / reflection analyzer (ET) sub-type or S-parameter analyzer opposite (ES model) alternative product so you can make the best choice on the relationship between performance and cost, to meet your measurement needs. Standard series features Agilent 8712ET and 8714ET features its amplitude and phase can be measured by a series of built-in transmission / reflection test set. These two points opposite instrument also uses advanced vector error correction techniques to improve measurement accuracy. Agilent 8712ES and 8714ES features its S-parameter test set capable of full two-port vector error correction, which can provide the highest level of measurement accuracy. All of these points can be on opposite Miriam RF components for rapid and comprehensive characterization of the sweep and power sweep. In addition, it also has the following characteristics: 50Ω or 75Ω Option form 300kHz ~ 1.3 or 3GHz model synthetic sources can provide accurate measurement of RF components for a variety of fast, stable, high-resolution (1Hz) incentives. Power Sweep able to amplifier gain compression and AM-FM conversion testing 60dB step attenuator (ES type of standard parts, ET type of optional parts) can provide a wide range of output power levels greater than for testing active devices Real-time updates 10 times per second scanning speed devices help to achieve high productivity and improve the efficiency of the built-in tuner is compatible with DOS 3.5-inch disk drives can provide unlimited data storage serial, parallel, LAN and GPIB interface is very easy to All the various printers and plotters provides printing and plotting data. Flexible and sensitive narrowband receiver can detect, but also for broadband testing. Wideband detection of a frequency converter can be characterized, and the narrow band detection can provide a dynamic range of 100dB The instrument is equipped with a large screen 9 inches monochrome display, in order to clearly observe the measurement data of the test device of high inhibitory vector measurement, special Function keys, IBASIC procedures and frequency standard. With any color monitor with a VGA-compatible display connected may pass / fail marks and tracking data. Two independent measurement channels can be displayed simultaneously transmission and reflection data. Each channel can have independent measurement parameters, such as frequency range, IF bandwidth, data points and display format. Display formats include SWR (SWR), linear and logarithmic magnitude of amplitude, phase and group delay, Smith chart, polar circle, real and imaginary, dBW, dBm, dBμm, dBV, dBmV, dBμV. Suitable for production of the characteristics of the network connection may provide a means to test the system with your linked to effective and reliable. With the standard TCP / IP compatible EthertwistLAN connected to the network interface so that the plant is very easy. Using a variety of standard protocols (such as ftp, http, bootp, telnet, Sockets) and Network File System (NFS), may be a new test procedures, test parameters, limit lines, and user interface simultaneously assigned to your production line all instruments on. Use LAN function, data can be directly into your PC application software, such as MicrosoftWord and Excel, or sent to a networked printer. You can use any standard Internet browser economic remotely from anywhere in the wind test station to find the problem. The use of instruments with the BASIC programming council (IBASIC), it is easy to constitute routine testing applications and user interfaces, including: special function keys labeled diagrams and graphical user settings for the restructuring of tips to effectively track and record the performance of each device barcode reader function via LAN, GPIB, serial or parallel interface to other test equipment to control IBASIC as keystroke loggers, easily achieved manually measurement automation. Many manufacturing test just call the appropriate instrument state will be able to be completed without changing the measurement parameters manually. For a variety of applications, there are hundreds of instrument status can be programmed. With HP's "fast tuning" feature, during adjustment or assembly operations with a function key or for optional foot switch (not hand-conversion), will be able to quickly call the seven kinds of instruments in one state. Instrument status can include user-defined limit line, the limit line makes it easy to consistently the measured data were compared with the test limits, thus completing the automated pass / fail tests. Pass / Fail results clearly displayed on the instrument screen or external monitor to operator error or misinterpretation reduced to a minimum. Automated pass / fail test will guess eliminated from the testing process, helps to ensure that all components are tested against the same station on technical indicators to make adjustments and testing. With built-in data markers powerful component test time can be shortened. With eight markers per channel data to display absolute or relative data. Alternatively, some of the characteristics of the device, such as the ratio of the maximum and minimum values, the center frequency, the mean and standard deviation, the peak-peak offset, gain, slope, and flatness, the 3dB bandwidth of the filter, the loss Q value, and automatic , real-time computing. Comprehensive and rapid cable testing Option 100 for the characterization or the warehouse is still on the reel is mounted cellular antenna rod 50Ω or 75Ω cable fault location and provides structural return loss (SRL) measurements. Agilent's fault Positioning Option ease of use, and compared with the traditional time domain reflectometry domain (TDR) technology has many advantages. You can also use this option to determine cable loss factor and speed factor, as well as to accurately check the cable damage by measuring the impact of SRL . Option 101 Option 100 is equipped with a sturdy carrying case for on-site equipment during transport and operation of protection. Technical indicators signal source characteristics Frequency range: 300KHz-1.3GHz frequency resolution: 1Hz frequency accuracy: <5ppm harmonic: <1MHz 8712ET / ES: 1MHz: 108dB broadband, 50Ω> 54dB maximum input (0.5dB) compression narrowband broadband 16dBm 10dBm Input damage levels 26dBm System Technical Specifications (N type, 50Ω) 300MHz ~ 1.3GHz Directional (as amended) 50dB source match (as amended) 42dB load match (as amended, applies only to ES-type) 50dB load match (uncorrected ) 18dB cycle time (201 points, a port response calibration wide bandwidth) 72ms traces Transfer (201 points, real format) 20ms structural characteristics of the test port connector: 50Ω or 75Ω N-type (female) |
Admin>>>
You are the 6203 visitor
Copyright © GuangDong ICP No. 10089450, No. 144 Yingbin Road, Dongguan City, Tong Fu Road Tangxia All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 6203 visitor
Copyright © GuangDong ICP No. 10089450, No. 144 Yingbin Road, Dongguan City, Tong Fu Road Tangxia All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility